Giant Series (3P/3P)

PRO63300-GL Giant Series 10-40KVA

Online double-conversion

DSP technology guarantees high reliability

True galvanic isolation transformer design

Control designed to withstand all kinds of loads

Intelligent battery management to prolong battery lifecycle

Redundant fan design and independent ventilation enhance durable operation under harsh environment

MODEL

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 10KVA
Nominal Power (W) 8KW
Dimension (mm) 557 x 360 x 898 (D x W x H)
Weight (kg) 108

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC (3Ph+N)
Acceptable Voltage Range 165VAC ~ 280VAC(Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Frequency 40Hz ~ 70 Hz

OUTPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC (3Ph+N)
Frequency 50/60 Hz ±1%
Voltage Regulation
±1%
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<4% (Non-linear Load)

BYPASS

Connection Type Hardwire 4-wire (3Phn+N)
Input Voltage Range 176~264VAC(Ph-N); 304~456VAC(Ph-Ph)
Overload Capability
0% ~ 150% continuous working; 150% ~ 180% 60min~5min; >180% 5min

BATTERY

Battery Type and Numbers 12V sealed lead-acid battery x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Voltage Range 290 ~ 435 VDC
Charging Current

Default 10A, *Maximum=Capacity(KW)/Battery voltage(real-time)

*The maximum current is never higher than 40A

   

 

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 15KVA
Nominal Power (W) 12KW
Dimension (mm) 557 x 360 x 898 (D x W x H)
Weight (kg) 130

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC (3Ph+N)
Acceptable Voltage Range 165VAC ~ 280VAC(Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Frequency 40Hz ~ 70 Hz

OUTPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC (3Ph+N)
Frequency 50/60 Hz ±1%
Voltage Regulation
±1%
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<4% (Non-linear Load)

BYPASS

Connection Type Hardwire 4-wire (3Phn+N)
Input Voltage Range 176~264VAC(Ph-N); 304~456VAC(Ph-Ph)
Overload Capability
0% ~ 150% continuous working; 150% ~ 180% 60min~5min; >180% 5min

BATTERY

Battery Type and Numbers 12V sealed lead-acid battery x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Voltage Range 290 ~ 435 VDC
Charging Current

Default 10A, *Maximum=Capacity(KW)/Battery voltage(real-time)

*The maximum current is never higher than 40A

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 20KVA
Nominal Power (W) 16KW
Dimension (mm) 557 x 360 x 898 (D x W x H)
Weight (kg) 146

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC (3Ph+N)
Acceptable Voltage Range 165VAC ~ 280VAC(Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Frequency 40Hz ~ 70 Hz

OUTPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC (3Ph+N)
Frequency 50/60 Hz ±1%
Voltage Regulation
±1%
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<4% (Non-linear Load)

BYPASS

Connection Type Hardwire 4-wire (3Phn+N)
Input Voltage Range 176~264VAC(Ph-N); 304~456VAC(Ph-Ph)
Overload Capability
0% ~ 150% continuous working; 150% ~ 180% 60min~5min; >180% 5min

BATTERY

Battery Type and Numbers 12V sealed lead-acid battery x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Voltage Range 290 ~ 435 VDC
Charging Current

Default 10A, *Maximum=Capacity(KW)/Battery voltage(real-time)

*The maximum current is never higher than 40A

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 30KVA
Nominal Power (W) 24KW
Dimension (mm) 683 x 450 x 1100 (D x W x H)
Weight (kg) 220

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC (3Ph+N)
Acceptable Voltage Range 165VAC ~ 280VAC(Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Frequency 40Hz ~ 70 Hz

OUTPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC (3Ph+N)
Frequency 50/60 Hz ±1%
Voltage Regulation
±1%
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<4% (Non-linear Load)

BYPASS

Connection Type Hardwire 4-wire (3Phn+N)
Input Voltage Range 176~264VAC(Ph-N); 304~456VAC(Ph-Ph)
Overload Capability
0% ~ 150% continuous working; 150% ~ 180% 60min~5min; >180% 5min

BATTERY

Battery Type and Numbers 12V sealed lead-acid battery x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Voltage Range 290 ~ 435 VDC
Charging Current

Maximum 40A, 5A @ full load

GENERAL

UPS Type Tower
Phase 3 phase in / 3 phase out
Rating (VA) 40KVA
Nominal Power (W) 32KW
Dimension (mm) 683 x 450 x 1100 (D x W x H)
Weight (kg) 256

INPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC (3Ph+N)
Acceptable Voltage Range 165VAC ~ 280VAC(Ph-N); 285VAC ~ 485VAC (Ph-Ph)
Frequency 40Hz ~ 70 Hz

OUTPUT

Connection Type Terminal
Nominal Voltage 3 x 380VAC (3Ph+N)
Frequency 50/60 Hz ±1%
Voltage Regulation
±1%
Admissible Crest Factor 3:1
Harmonic Distortion <2% (Linear Load)

<4% (Non-linear Load)

BYPASS

Connection Type Hardwire 4-wire (3Phn+N)
Input Voltage Range 176~264VAC(Ph-N); 304~456VAC(Ph-Ph)
Overload Capability
0% ~ 150% continuous working; 150% ~ 180% 60min~5min; >180% 5min

BATTERY

Battery Type and Numbers 12V sealed lead-acid battery x 32 pcs (29~32 pcs adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Voltage Range 290 ~ 435 VDC
Charging Current

Maximum 40A, 5A @ full load

DOWNLOAD

Document Date Version
- -
2022-03-22 1.00

You may also like…

PRO600-S/L SERIES 6-10KVA

PRO63100-L-384 SERIES 10-120KVA

PRO63300-L-384 SERIES 10-300KVA

PRO63100-S/L SERIES 6-10KVA

PRO63100-GL SERIES 10-40KVA