MODEL
GENERAL
| Capacity | 650VA |
| Dimension (mm) | 279 x 101 x 142 (D x W x H) |
| Weight (kg) | 4.2 |
INPUT
| Nominal Voltage | 230VAC |
| Voltage Range | 140 - 300 VAC ± 5% |
| Nominal Frequency | 50 or 60Hz (Auto sensing) |
OUTPUT
| Voltage Regulation | ± 10% |
| Frequency | 50 or 60Hz ± 1Hz |
| Transfer Time (typical) | 2 - 6ms |
| Waveform | Simulated Sinewave |
BATTERY
| Number of Battery | 12 V/8.2 Ah x 1 |
| Recharge Time (typical) | 2-4 hours recover to 90% capacity |
ALARM & INDICATORS
| LED Display | AC Mode - Green Lighting
Battery Mode - Yellow Flashing every 10 seconds Overload - Red Flashing every second Fault - Red Lighting |
| Sounding | Battery Mode - Sounding every 10 seconds
Low Battery - Sounding every second Overload - Sounding every 0.5 second Battery Replacement Alarm - Sounding every 2 seconds Fault - Continously sounding |
Rear Panel
|
GENERAL
| Capacity | 850VA |
| Dimension (mm) | 279 x 101 x 142 (D x W x H) |
| Weight (kg) | 4.9 |
INPUT
| Nominal Voltage | 230VAC |
| Voltage Range | 140 - 300 VAC ± 5% |
| Nominal Frequency | 50 or 60Hz (Auto sensing) |
OUTPUT
| Voltage Regulation | ± 10% |
| Frequency | 50 or 60Hz ± 1Hz |
| Transfer Time (typical) | 2 - 6ms |
| Waveform | Simulated Sinewave |
BATTERY
| Number of Battery | 12 V/10 Ah x 1 |
| Recharge Time (typical) | 2-4 hours recover to 90% capacity |
ALARM & INDICATORS
| LED Display | AC Mode - Green Lighting
Battery Mode - Yellow Flashing every 10 seconds Overload - Red Flashing every second Fault - Red Lighting |
| Sounding | Battery Mode - Sounding every 10 seconds
Low Battery - Sounding every second Overload - Sounding every 0.5 second Battery Replacement Alarm - Sounding every 2 seconds Fault - Continously sounding |
Rear Panel
|
GENERAL
| Capacity | 1200VA |
| Dimension (mm) | 320 x 130 x 182 (D x W x H) |
| Weight (kg) | 8.2 |
INPUT
| Nominal Voltage | 230VAC |
| Voltage Range | 140 - 300 VAC ± 5% |
| Nominal Frequency | 50 or 60Hz (Auto sensing) |
OUTPUT
| Voltage Regulation | ± 10% |
| Frequency | 50 or 60Hz ± 1Hz |
| Transfer Time (typical) | 2 - 6ms |
| Waveform | Simulated Sinewave |
BATTERY
| Number of Battery | 12 V/8.2 Ah x 2 |
| Recharge Time (typical) | 2-4 hours recover to 90% capacity |
ALARM & INDICATORS
| LED Display | AC Mode - Green Lighting
Battery Mode - Yellow Flashing every 10 seconds Overload - Red Flashing every second Fault - Red Lighting |
| Sounding | Battery Mode - Sounding every 10 seconds
Low Battery - Sounding every second Overload - Sounding every 0.5 second Battery Replacement Alarm - Sounding every 2 seconds Fault - Continously sounding |
Rear Panel
|
GENERAL
| Capacity | 1250VA |
| Dimension (mm) | 320 x 130 x 182 (D x W x H) |
| Weight (kg) | 9.2 |
INPUT
| Nominal Voltage | 230VAC |
| Voltage Range | 140 - 300 VAC ± 5% |
| Nominal Frequency | 50 or 60Hz (Auto sensing) |
OUTPUT
| Voltage Regulation | ± 10% |
| Frequency | 50 or 60Hz ± 1Hz |
| Transfer Time (typical) | 2 - 6ms |
| Waveform | Simulated Sinewave |
BATTERY
| Number of Battery | 12 V/8.2 Ah x 2 |
| Recharge Time (typical) | 2-4 hours recover to 90% capacity |
ALARM & INDICATORS
| LED Display | AC Mode - Green Lighting
Battery Mode - Yellow Flashing every 10 seconds Overload - Red Flashing every second Fault - Red Lighting |
| Sounding | Battery Mode - Sounding every 10 seconds
Low Battery - Sounding every second Overload - Sounding every 0.5 second Battery Replacement Alarm - Sounding every 2 seconds Fault - Continously sounding |
Rear Panel
|
GENERAL
| Capacity | 1500VA |
| Dimension (mm) | 320 x 130 x 182 (D x W x H) |
| Weight (kg) | 10.4 |
INPUT
| Nominal Voltage | 230VAC |
| Voltage Range | 140 - 300 VAC ± 5% |
| Nominal Frequency | 50 or 60Hz (Auto sensing) |
OUTPUT
| Voltage Regulation | ± 10% |
| Frequency | 50 or 60Hz ± 1Hz |
| Transfer Time (typical) | 2 - 6ms |
| Waveform | Simulated Sinewave |
BATTERY
| Number of Battery | 12 V/10 Ah x 2 |
| Recharge Time (typical) | 2-4 hours recover to 90% capacity |
ALARM & INDICATORS
| LED Display | AC Mode - Green Lighting
Battery Mode - Yellow Flashing every 10 seconds Overload - Red Flashing every second Fault - Red Lighting |
| Sounding | Battery Mode - Sounding every 10 seconds
Low Battery - Sounding every second Overload - Sounding every 0.5 second Battery Replacement Alarm - Sounding every 2 seconds Fault - Continously sounding |
Rear Panel
|
GENERAL
| Capacity | 2000VA |
| Dimension (mm) | 320 x 130 x 182 (D x W x H) |
| Weight (kg) | 10.6 |
INPUT
| Nominal Voltage | 220VAC / 230VAC |
| Voltage Range | 140 - 300 VAC ± 5% |
| Nominal Frequency | 50 or 60Hz (Auto sensing) |
OUTPUT
| Voltage Requlation | ± 10% |
| Frequency | 50 or 60Hz ± 1Hz |
| Transfer Time (typical) | 2 - 6ms |
| Waveform | Simulated Sinewave |
BATTERY
| Number of Battery | 12 V/10 Ah x 2 |
| Recharge Time (typical) | 2-4 hours recover to 90% capacity |
ALARM & INDICATORS
| LED Display | AC Mode - Green Lighting
Battery Mode - Yellow Flashing every 10 seconds Overload - Red Flashing every second Fault - Red Lighting |
| Sounding | Battery Mode - Sounding every 10 seconds
Low Battery - Sounding every second Overload - Sounding every 0.5 second Battery Replacement Alarm - Sounding every 2 seconds Fault - Continously sounding |
Rear Panel
|