Master II Series (1P/1P) – Rack/Tower

PRO800-ERS/ERL SERIES 1-3KVA

User-friendly and easy-shift lcd display

True Double-Conversion

Output power factor 0.9

Emergency power off (EPO) functiong

50/60Hz Frequency Converter Mode

Programmable power management outlets

MODEL

GENERAL

UPS Type Rack / Tower
Phase 1 phase in / 1 phase out
Rating (VA) 1000
Nominal Power (W) 900
Standard Model

Dimension (mm)

UPS Unit: 410 x 438 x 88 [2U] (D x W x H)

Battery Pack: 600 x 438 x 133 [3U] (D x W x H)

Weight (kg) UPS Unit: 11.6
Long-run Model

Dimension (mm)

410 x 438 x 88 [2U] (D x W x H)
Weight (kg) 6.4

INPUT

Connection Type IEC 320-C14
Nominal Voltage 230 VAC
Voltage Range 160-300 VAC @100% load

110 VAC @ 60% load (Derating)

Frequency Range 40Hz ~ 70Hz
Power Factor ≧0.99 @ nominal voltage (100% load)

OUTPUT

Connection Type 6 x IEC 320-C13
Nominal Voltage 220/230/240 VAC (Selectable)
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode) 50 Hz / 60Hz ± 0.1%
Current Crest Ratio 3:1
Harmonic Distortion ≦3% THD (Linear load)

≦6% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 2
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries

Numbers 2 / 3
Charging Current (max) 1 / 2 / 4 / 8 A

REAR PANEL

  1. Programmable outlets: connect to non-critical loads
  2. Output receptacles: connect to mission-critical loads
  3. AC input
  4. Input circuit breaker
  5. Network/Fax/Modem surge protection
  6. Emergency power off function connector (EPO)
  7. USB communication port
  8. RS-232 communication port
  9. Intelligent slot
  10. External battery connection
  11. Cooling fan

GENERAL

UPS Type Rack / Tower
Phase 1 phase in / 1 phase out
Rating (VA) 2000
Nominal Power (W) 1800
Standard Model

Dimension (mm)

UPS Unit: 510 x 438 x 88 [2U] (D x W x H)
Weight (kg) UPS Unit: 14.5
Long-run Model

Dimension (mm)

410 x 438 x 88 [2U] (D x W x H)
Weight (kg) 6.5

INPUT

Connection Type IEC 320-C14
Nominal Voltage 230 VAC
Voltage Range 160-300 VAC @100% load

110 VAC @ 60% load (Derating)

Frequency Range 40Hz ~ 70Hz
Power Factor ≧0.99 @ nominal voltage (100% load)

OUTPUT

Connection Type 6 x IEC 320-C13
Nominal Voltage 220/230/240 VAC (Selectable)
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode) 50 Hz / 60Hz ± 0.1%
Current Crest Ratio 3:1
Harmonic Distortion ≦3% THD (Linear load)

≦6% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 4
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries

Numbers 4 / 6
Charging Current (max) 1 / 2 / 4 / 8 A

REAR PANEL

  1. Programmable outlets: connect to non-critical loads
  2. Output receptacles: connect to mission-critical loads
  3. AC input
  4. Input circuit breaker
  5. Network/Fax/Modem surge protection
  6. Emergency power off function connector (EPO)
  7. USB communication port
  8. RS-232 communication port
  9. Intelligent slot
  10. External battery connection
  11. Cooling fan

GENERAL

UPS Type Rack / Tower
Phase 1 phase in / 1 phase out
Rating (VA) 3000
Nominal Power (W) 2700
Standard Model

Dimension (mm)

UPS Unit: 630 x 438 x 88 [2U] (D x W x H)
Weight (kg) UPS Unit: 27.4
Long-run Model

Dimension (mm)

510 x 438 x 88 [2U] (D x W x H)
Weight (kg) 10.5

INPUT

Connection Type IEC 320-C14
Nominal Voltage 230 VAC
Voltage Range 160-300 VAC @100% load

110 VAC @ 60% load (Derating)

Frequency Range 40Hz ~ 70Hz
Power Factor ≧0.99 @ nominal voltage (100% load)

OUTPUT

Connection Type 6 x IEC 320-C13
Nominal Voltage 220/230/240 VAC (Selectable)
Voltage Regulation ±1%
Frequency Range (Synchronized Range) 47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode) 50 Hz / 60Hz ± 0.1%
Current Crest Ratio 3:1
Harmonic Distortion ≦3% THD (Linear load)

≦6% THD (Non-linear load)

ALARM & INDICATORS

Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
LCD Load level, Battery Level, AC mode, Battery mode, Bypass mode and Fault

CONNECTIVITY, CONTROL & MONITORING

Front panel Status LED, Function keys, LCD display
Communication Smart RS232*

USB Port

Emergency Power Off (EPO)

BATTERY

Standard Model

Type

12V / 9Ah
Numbers 6
Typical Recharge Time  4 hours recover to 90% capacity
Long-run Model

Type

Depending on the capacity of external batteries
Numbers 6
Charging Current (max) 1 / 2 / 4 / 8 A

REAR PANEL

  1. Programmable outlets: connect to non-critical loads
  2. Output receptacles: connect to mission-critical loads
  3. AC input
  4. Input circuit breaker
  5. Network/Fax/Modem surge protection
  6. Emergency power off function connector (EPO)
  7. USB communication port
  8. RS-232 communication port
  9. Intelligent slot
  10. External battery connection
  11. Cooling fan

DOWNLOAD

Document Date Version
- -
2021-05-19 1.00
2017-02-03 1.00

You may also like…

PRO800-ES/EL SERIES 1-3KVA

PRO83300-ERS/ERL SERIES 10-20KVA

PRO83300-ES/EL SERIES 10-30KVA

PRO83300-QS/QL SERIES 10-80KVA

PRO83100-ERS/ERL SERIES 10-20KVA