MODEL
GENERAL
| UPS Type | Tower |
| Phase | 3 phase in / 1 phase out |
| Rating (VA) | 10000VA |
| Nominal Power (W) | 9000W |
| Standard Model
Dimension (mm) |
592 x 250 x 576 (D x W x H) |
| Weight (kg) | 83 |
| Long-run Model
Dimension (mm) |
592 x 250 x 576 (D x W x H) |
| Weight (kg) | 28 |
INPUT
| Connection Type | Terminal |
| Nominal Voltage | 3x 380/400/415 (3Ph+N) |
| Voltage Range | 190-520 VAC (3-phase) @ 50% load
305-478 VAC (3-phase) @ 100% load |
| Frequency Range | 46~54Hz or 56~64Hz |
| Power Factor | ≧0.99 @ 100% Load |
| THDi | < 6% @ 100% load |
OUTPUT
| Connection Type | Terminal
2 x IEC 320-C13 |
| Output Voltage | 208/220/230/240VAC |
| Voltage Regulation | ±1% |
| Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) |
| Harmonic Distortion | ≦2% THD (Linear load)
≦5% THD (Non-linear load) |
ALARM & INDICATORS
| Battery Mode | Sounding every 4 seconds |
| Low Battery | Sounding every second |
| Overload | Sounding twice every second |
| Fault | Continuously sounding |
| LCD | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
CONNECTIVITY, CONTROL & MONITORING
| Front panel | Status LED, Function keys, LCD display |
| Communication | Smart RS232*
USB Port Emergency Power Off (EPO) |
BATTERY
| Standard Model
Type |
12V / 9Ah |
| Numbers | 20 (18 - 20 adjustable)* |
| Typical Recharge Time | 9 hours recover to 90% capacity |
| Long-run Model
Type |
Depending on the capacity of external batteries |
| Numbers | Depending on the capacity of external batteries |
| Charging Current (max) | 4A |
REAR PANEL
|
GENERAL
| UPS Type | Tower |
| Phase | 3 phase in / 1 phase out |
| Rating (VA) | 15000VA |
| Nominal Power (W) | 13500W |
| Standard Model
Dimension (mm) |
815 x 250 x 826 (D x W x H) |
| Weight (kg) | 164 |
| Long-run Model
Dimension (mm) |
592 x 250 x 576 (D x W x H) |
| Weight (kg) | 40 |
INPUT
| Connection Type | Terminal |
| Nominal Voltage | 3x 380/400/415 (3Ph+N) |
| Voltage Range | 190-520 VAC (3-phase) @ 50% load
305-478 VAC (3-phase) @ 100% load |
| Frequency Range | 46~54Hz or 56~64Hz |
| Power Factor | ≧0.99 @ 100% Load |
| THDi | < 6% @ 100% load |
OUTPUT
| Connection Type | Terminal |
| Output Voltage | 208/220/230/240VAC |
| Voltage Regulation | ±1% |
| Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) |
| Harmonic Distortion | ≦2% THD (Linear load)
≦5% THD (Non-linear load) |
ALARM & INDICATORS
| Battery Mode | Sounding every 4 seconds |
| Low Battery | Sounding every second |
| Overload | Sounding twice every second |
| Fault | Continuously sounding |
| LCD | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
CONNECTIVITY, CONTROL & MONITORING
| Front panel | Status LED, Function keys, LCD display |
| Communication | Smart RS232*
USB Port Emergency Power Off (EPO) |
BATTERY
| Standard Model
Type |
12V / 9Ah |
| Numbers | 20 (18 - 20 adjustable)* x 2 strings |
| Typical Recharge Time | 9 hours recover to 90% capacity |
| Long-run Model
Type |
Depending on the capacity of external batteries |
| Numbers | Depending on the capacity of external batteries |
| Charging Current (max) | 8A |
REAR PANEL
|
GENERAL
| UPS Type | Tower |
| Phase | 3 phase in / 1 phase out |
| Rating (VA) | 20000VA |
| Nominal Power (W) | 18000W |
| Standard Model
Dimension (mm) |
815 x 250 x 826 (D x W x H) |
| Weight (kg) | 164 |
| Long-run Model
Dimension (mm) |
592 x 250 x 576 (D x W x H) |
| Weight (kg) | 40 |
INPUT
| Connection Type | Terminal |
| Nominal Voltage | 3x 380/400/415 (3Ph+N) |
| Voltage Range | 190-520 VAC (3-phase) @ 50% load
305-478 VAC (3-phase) @ 100% load |
| Frequency Range | 46~54Hz or 56~64Hz |
| Power Factor | ≧0.99 @ 100% Load |
| THDi | < 6% @ 100% load |
OUTPUT
| Connection Type | Terminal |
| Output Voltage | 208/220/230/240VAC |
| Voltage Regulation | ±1% |
| Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) |
| Harmonic Distortion | ≦2% THD (Linear load)
≦5% THD (Non-linear load) |
ALARM & INDICATORS
| Battery Mode | Sounding every 4 seconds |
| Low Battery | Sounding every second |
| Overload | Sounding twice every second |
| Fault | Continuously sounding |
| LCD | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
CONNECTIVITY, CONTROL & MONITORING
| Front panel | Status LED, Function keys, LCD display |
| Communication | Smart RS232*
USB Port Emergency Power Off (EPO) |
BATTERY
| Standard Model
Type |
12V / 9Ah |
| Numbers | 20 (18 - 20 adjustable)* x 2 strings |
| Typical Recharge Time | 9 hours recover to 90% capacity |
| Long-run Model
Type |
Depending on the capacity of external batteries |
| Numbers | Depending on the capacity of external batteries |
| Charging Current (max) | 8A |
REAR PANEL
|
GENERAL
| UPS Type | Tower |
| Phase | 3 phase in / 1 phase out |
| Rating (VA) | 30000VA |
| Nominal Power (W) | 27000W |
| Standard Model
Dimension (mm) |
815 x 300 x 1000 (D x W x H) |
| Weight (kg) | 234 |
| Long-run Model
Dimension (mm) |
815 x 250 x 826 (D x W x H) |
| Weight (kg) | 64 |
INPUT
| Connection Type | Terminal |
| Nominal Voltage | 3x 380/400/415 (3Ph+N) |
| Voltage Range | 190-520 VAC (3-phase) @ 50% load
305-478 VAC (3-phase) @ 100% load |
| Frequency Range | 46~54Hz or 56~64Hz |
| Power Factor | ≧0.99 @ 100% Load |
| THDi | < 6% @ 100% load |
OUTPUT
| Connection Type | Terminal |
| Output Voltage | 208/220/230/240VAC |
| Voltage Regulation | ±1% |
| Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) |
| Harmonic Distortion | ≦2% THD (Linear load)
≦5% THD (Non-linear load) |
ALARM & INDICATORS
| Battery Mode | Sounding every 4 seconds |
| Low Battery | Sounding every second |
| Overload | Sounding twice every second |
| Fault | Continuously sounding |
| LCD | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions |
CONNECTIVITY, CONTROL & MONITORING
| Front panel | Status LED, Function keys, LCD display |
| Communication | Smart RS232*
USB Port Emergency Power Off (EPO) |
BATTERY
| Standard Model
Type |
12V / 9Ah |
| Numbers | 20 (18 - 20 adjustable)* x 3 strings |
| Typical Recharge Time | 9 hours recover to 90% capacity |
| Long-run Model
Type |
Depending on the capacity of external batteries |
| Numbers | Depending on the capacity of external batteries |
| Charging Current (max) | 12A |
REAR PANEL
|